Q. What
date has been set for RoHS directive to become activated?
Answer:
Product
arriving in EU on
July
1, 2006
shall
be in compliance with RoHS directive.
Q.
What
comprises a Lead-Free
Assembly to meet RoHs and WEEE?
Answer: The
Components, PCBs and the Assembly Process must not contain lead greater then .1
percent. Additionally, components or the entire assembly must not contain any of
the listed group of chemicals such as PBB and PBDE and metals such as Hexavalent
Chromium, cadmium and mercury.
Q.
Are lead-free devices compatible with conventional (Sn/Pb) soldering processes?
Answer:
In
most cases the answer is “Yes.” Full forward / backward compatibility should
be ensured by performing a complete review of components listed on a BOM (Bill
of Materials). Lead-free devices have either pure tin or NiPdAu (Nickel,
Palladium & Gold) plating. Note: one exception will be BGA’s and BGA style
packages. Standard Sn63 reflow temperature is too low to allow for proper
melting of the higher temperature SAC (Tin, Silver & Copper) alloy used for
solderballs on BGA’s and BGA style packages.
Q. Will device part
marking change? What will distinguish RoHS / Pb-free products from current SnPb
finish products?
Answer: The
answer is “Yes” and “No.’ Many
companies are planning to have the new RoHS / Pb-free finish devices completely
replace those currently offered with tin-lead. Once a product is converted, it
will only be available with a RoHS / Pb-free finish. Since there will be no
difference in form, fit or function and the parts will be qualified for either
solder reflow manufacturing process, once the conversion is complete there will
be no distinction in the product marking. The only distinction will be the
manufacturing date code. Other companies will identify their RoHS/Pb-free
products with a unique part number to easily identify from tin-lead components.
Q. Will board laminate
material be required to change for Pb-free assembly process?
Answer: Pb-free
soldering process has a much higher reflow temperature than standard tin-lead
process. Laminates such as standard FR4, used mostly in tin-lead assemblies,
will not be adequate to support Pb-free processes. Many individuals may suggest
moving from a standard FR4 with a Tg (transitition to glass) of 145 degrees C to
a laminate rated at 180 Tg. The Tg is no longer meaningful when we consider
Lead-Free solder. We now worry about the degrading of the material and how much
heat it can withstand over a period of time. This is identified as Td
(temperature to decomposition).
Q. Do all laminate suppliers
have material that will meet Pb-free requirements?
Answer: Virtually
all laminate suppliers have various products that should meet everyone’s
requirements. We
do not endorse any one laminate manufacturer. Polyclad 370 HR is one product
that appears to be getting more attention than others.
Q. Do I need to purchase a
Halogen Free laminate to meet RoHS directives?
Answer: No!
There
is no requirement to force use of Halogen Free laminates. These laminates are
available but are generally more expensive and provide no added benefit.
Q. What type of surface
finishes are available on bare boards? Are all surface finishes the same?
Answer: The
list below provides detail on commonly acknowledged surface finishes. Currently
ENIG and Immersion Ag (Silver) are the most widely used. Schippers & Crew,
Inc. currently recommends use of ENIG finish.